Our Testing Services: DGUV V3 & Plant Safety in Munich
Safety that thinks ahead. We combine legally secure testing in the greater Munich area according to DGUV, TRBS and VDE with maximum transparency: your testing logs are always within reach.
01 · Equipment TestingPortable Equipment
DGUV V3 testing of portable equipment is a legally required safety inspection for all electrical work equipment that can be moved during operation.
Classic DGUV V3 testing for devices with plugs (e.g., PC, monitor, drill, cable reel).
- Visual, measurement & functional testing with calibrated test instruments.
- Audit-proof documentation & attachment of the test badge.
02 · System TestingStationary Electrical Systems
System testing according to VDE 0105-100 includes the safety evaluation and measurement of your permanently installed electrical installations in the building.
Safety for your building infrastructure directly in your operating rooms.
- Sub-distribution boards, control cabinets & permanently connected machines.
- Loop impedance & RCD (residual current device) measurement for personal protection.
03 · EquipmentLadders & Steps
Ladder inspection according to BetrSichV is a recurring expert control of mechanical climbing aids for active accident prevention in the workplace.
Inspection of ladders, steps and mobile scaffolds for safe use.
- Visual and functional control (side rails, rungs, non-slip feet).
- Creation of the legal ladder control sheet & test badge.
04 · Warehouse TechnologyRack Inspection (Heavy-duty Racks)
Rack inspection according to DIN EN 15635 is the mandatory annual expert inspection for commercial rack systems to prevent material damage and occupational accidents.
For pallet racks, shelving racks and cantilever racks.
- Visual inspection for collision damage and deformations.
- Inspection of loading signs & safety elements (push-through protections).
- Detailed defect report with immediate action recommendations.
05 · Legal ComplianceRisk Assessment
The risk assessment is the legal foundation for the risk-based determination of testing intervals and protective measures for electrical equipment.
We create and document the risk assessment for your installations.
- Risk-based determination of test intervals based on usage & environment.
- Creation of legally secure, documented action plans.
- Regular adjustment in case of operational changes.
06 · Repair ServicesOn-site Repair & Replacement
Repair services include the immediate and economically sensible repair of defective equipment directly on-site in accordance with DGUV specifications.
We minimize your downtime through pragmatic solutions.
- Replacement of defective safety plugs & couplings (230V / 400V).
- Shortening or replacing damaged power cables according to VDE specifications.
- Immediate re-testing and release after repair.
07 · AmpGuard-Zenitnel DigitalDigital Records & Cloud
Digital testing documentation via AmpGuard-Zentinel offers companies secure, GDPR-compliant, centralized access to all test reports and inventory lists.
Put an end to paper chaos in Leitz folders. We digitalize your test management.
- Customer Portal: Secure, password-protected access to all PDF reports.
- Smart Device ID: Call up test status and protocol directly via smartphone scan on the device.
08 · Carefree PackagesMaintenance Contracts & Subscriptions
Our maintenance contracts ensure automated interval management, so that inspections are planned, budgeted and carried out without missing deadlines.
We handle the complete schedule management for you.
- Automatic scheduling and reminders before the interval expires.
- Fixed price guarantee for the contract term of 12 or 24 months.
- Prioritized service for short-term operations.
09 · KabeltrommelnKabeltrommel- & Verlängerungsleitungsprüfung
Verlängerungskabel und Kabeltrommeln zählen zu den am stärksten beanspruchten Betriebsmitteln im Alltag – und werden bei pauschalen Geräteprüfungen oft übersehen.
Wir prüfen Kabeltrommeln bis 25 Meter Länge separat, inklusive Sichtprüfung auf Knicke und Quetschungen sowie vollständiger Messung über die gesamte Kabellänge.
- Schutzleiter- und Isolationswiderstandsmessung über die volle Kabellänge
- Sichtprüfung auf mechanische Schäden, Knick- und Zugbelastung
10 · Drehstrom & 400VDrehstromgeräte & 400V-Betriebsmittel
Baustellen und Werkstätten arbeiten häufig mit Drehstromgeräten und CEE-Steckverbindungen – diese benötigen eigene Prüfverfahren mit Drehfeldkontrolle.
Von der Prüfung nach Reparatur bis zur regelmäßigen Wiederholungsprüfung: Wir decken das komplette Drehstrom-Spektrum ab, inklusive Verlängerungsleitungen und Kabeltrommeln mit CEE-Steckern.
- Erstprüfung nach Reparatur oder Instandsetzung (EN 50678)
- Regelmäßige Wiederholungsprüfung (EN 50699)
- Drehstrom-Verlängerungsleitungen & Kabeltrommeln (CEE 16A / 32A / 63A)
11 · BeleuchtungOrtsfeste Leuchten & Beleuchtungsanlagen
Fest installierte Leuchten und Beleuchtungsanlagen gehören zur Anlagenprüfung – inklusive Not- und Fluchtwegbeleuchtung, wo besondere Sorgfalt gilt.
Wir prüfen Schutzleiterverbindung, Isolationsgüte und bei Bedarf die Funktion von Sicherheitsbeleuchtung und Umschalteinrichtungen im Rahmen Ihrer Anlagenprüfung.
- Sicht- und Funktionsprüfung inkl. Not- & Fluchtwegbeleuchtung
- Schutzleiterwiderstand und Isolationsmessung je Stromkreis
The Digital AmpGuard-Zentinel Label System
Put an end to the paper chaos in Leitz folders. Every inspected device receives our intelligent QR code label. A smartphone scan is all it takes to instantly see the live status in our traffic light system.
Tested & Secure
The device is defect-free and can continue to be used safely.
🟢 View Demo (öffnet in neuem Tab)Testing interval expiring (< 30 days)
No defect present. However, the stored testing interval expires within 30 days.
🟡 View Demo (öffnet in neuem Tab)Defective / Interval expired
The device is defective or the stored testing interval (e.g. 1 year) is exceeded. Block immediately!
🔴 View Demo (öffnet in neuem Tab)