Frequently Asked Questions About DGUV V3 Testing in Munich
Precise answers for business owners on DGUV V3 testing, testing intervals, the Industrial Safety Ordinance, documentation, and costs. Your qualified partner in the greater Munich area for Dachau, Fürstenfeldbruck, Maisach, Aschheim, Garching, Freising, and all of Upper Bavaria.
This page does not replace legal advice – it helps you realistically assess risks and make informed decisions.
Note: A structured testing concept helps businesses fulfill their operator obligations in a traceable way. We can support you with that.
⚖️ Fundamentals, Law & Obligations
What happens if DGUV V3 tests are not carried out?
Missing or overdue tests can have serious consequences. Besides an increased risk of electrical accidents, fires, and machine failures, damage cases can also raise insurance and liability questions.
Defective electrical equipment is often only detected through a proper test. Undetected damage to cables, connectors, or electrical installations can endanger people, cause business interruptions, and lead to high follow-up costs.
Regular testing under DGUV Regulation 3 therefore serves not only to fulfill statutory obligations, but above all to protect employees, assets, and the smooth operation of your business.
What is the purpose of testing under DGUV Regulation 3/4?
The DGUV V3 test serves the safe operation of electrical installations and the protection of people from electrical accidents. It is legally required and helps companies provide traceable documentation to trade associations, insurers, and authorities.
Is the DGUV V3 test legally required?
Yes. The testing obligation results directly from the Industrial Safety Ordinance (BetrSichV) in conjunction with DGUV Regulation 3 (formerly BGV A3).
What is the difference between portable equipment and stationary installations?
Portable electrical equipment can be moved or easily relocated during operation, for example computers, monitors, coffee machines, or extension cables. Stationary installations are permanently installed and part of a building's electrical infrastructure, for example sub-distribution boards, socket circuits, or machine connections.
Which regulations are relevant?
The relevant regulations are DGUV Regulation 3/4, BetrSichV, TRBS 1201/1203, as well as DIN EN 50678 / DIN EN 50699 (formerly DIN VDE 0701-0702) and DIN VDE 0105-100.
Who is responsible for implementation?
The employer is always responsible. They must ensure that testing is carried out on time and properly.
Who is allowed to carry out the electrical tests?
Only a qualified person under TRBS 1203. This is an electrician with appropriate electrotechnical training, current testing experience, and suitable, calibrated measurement equipment.
What happens if a deadline is exceeded?
Insurers can refuse to pay out in the event of damage, the trade association can assert recourse claims, and fines under the Industrial Safety Ordinance may apply.
🔌 Process & Testing Technology
Which measuring instruments does AmpGuard use for testing?
AmpGuard uses calibrated measuring instruments from Gossen Metrawatt (including SECUTEST PRO and PROFITEST PRIME). Calibration is carried out regularly and the corresponding certificates can be viewed at any time on request.
How long does a DGUV V3 test take?
Depending on the number of equipment items, machines, or installations to be tested, a DGUV V3 test takes between a few hours and several days. The initial recording usually takes a bit more time, as master data, serial numbers, manufacturer details, photos, and other object-specific information are captured for the first time. Follow-up tests can therefore usually be carried out much more efficiently.
Does business operations have to stop during testing?
No. Tests are planned so that ongoing operations are affected as little as possible. On request, AmpGuard also carries out the DGUV V3 test outside regular working hours, during shift breaks, in the evening, or on weekends. This keeps downtime to a minimum.
When will I receive the test report?
After the test is complete, the measurement data is checked, archived in a tamper-evident manner, and documented. You will then receive the complete test reports and test records in digital form.
How does equipment testing work (DIN EN 50678 / 50699)?
The test consists of a visual inspection, measurement testing with calibrated equipment, and a functional test. Only after passing all steps does the work equipment receive its test badge.
How does system testing work (VDE 0105-100)?
Testing of the permanently installed electrical installation, including measurements such as loop impedance, insulation resistance, and RCD trip times (residual current devices).
Are photos of tested equipment stored?
Yes. Photos and test data are clearly assigned to each test object and archived in a tamper-evident manner. After the test, the image files are assigned to the corresponding test object ID and stored in our documentation system. This means equipment, installations, and work equipment can always be identified via the unique ID and the associated QR code and linked to the complete test history.
Do multi-socket outlets need to be tested?
Yes. Multi-socket outlets and extension cables are among the most heavily used work equipment and are an often underestimated cause of fires.
What happens if defects are found?
Safety-relevant defects lead to the equipment being blocked immediately. The defects are precisely documented in the test report so that timely repair or disposal can take place.
📅 Testing Intervals & Service Areas
Which companies does AmpGuard serve?
AmpGuard serves offices, law firms, medical practices, trade businesses, property management companies, gyms, production companies, educational institutions, warehousing and logistics operations, construction sites, as well as municipalities, associations, and social institutions in the Munich area and Upper Bavaria.
How are the exact testing intervals determined?
Determination is risk-based, as part of the legally required risk assessment under BetrSichV.
What are typical guideline values for testing intervals?
- Office/administration: approx. 24 months
- Workshop/production: approx. 12 months
- Construction sites: approx. 3–6 months
Do you also travel to the Munich area for testing?
Yes. AmpGuard carries out DGUV V3 tests directly on site at your business – both within the city of Munich and throughout the surrounding area (e.g. Dachau, Fürstenfeldbruck, Maisach, Aschheim, Garching, Freising) as well as across Upper Bavaria.
Does equipment used at home offices need to be tested?
Yes, provided the electrical equipment (laptops, monitors, power supplies) is provided by the employer.
💼 AmpGuard Service, Documentation & Costs
Does AmpGuard carry out the tests itself?
Yes. Tests are carried out personally by Christian Grömmer, B.Eng. Electrical Engineering, state-certified electrical technician, and qualified person under TRBS 1203. AmpGuard does not use subcontractors or untrained assistants.
Why choose AmpGuard over a large testing company?
While larger testing companies often use rotating testing teams, testing at AmpGuard is carried out personally by a qualified electrical engineer. This means customers benefit from a fixed point of contact, short decision paths, and continuous technical responsibility.
What documents will I receive after the test?
You will receive structured, standard-compliant digital test records, test reports, measurement value overviews, defect overviews, and complete documentation of all recorded equipment. The documents serve as proof for trade associations, insurers, and trade supervisory authorities.
Do I receive the test reports digitally?
Yes. All test reports, test records, and documentation are provided digitally. After completion of internal quality assurance and tamper-evident archiving, you receive your complete documents in electronic form. On request, we can also provide the documentation in printed form after prior arrangement.
What is the advantage of QR / barcode labels?
The unique ID marking on each device rules out mix-ups. By scanning, the test status and complete history can be called up directly during follow-up tests or inspections.
How does digital deadline management & calendar export work?
Every tested object receives a weather- and abrasion-resistant QR badge. When the code is scanned, the current test status, along with photos and specifications, opens directly on the smartphone – no app installation required.
The AmpGuard batch feature: By entering a PIN, safety officers or workshop managers can unlock the company-wide deadline overview. The system identifies all equipment due in a given month and generates a batch calendar entry (.ics) for Outlook, Apple Calendar, or Google Calendar. This turns, for example, 40 individual devices into a single clean calendar appointment.
How are the testing costs calculated?
Costs are calculated transparently based on quantity, the type of equipment/installations, and the environment. You will always receive a binding quote in advance with no hidden travel surcharges.
Our offers and services are aimed exclusively at businesses and commercial operators (§ 14 BGB).
👷 Personen, Rollen & sicheres Arbeiten
Was darf ein elektrotechnischer Laie?
Ein elektrotechnischer Laie darf grundsätzlich keine elektrischen Anlagen öffnen, verändern, prüfen, reparieren oder eigenständig schalten. Erlaubt sind nur ausdrücklich freigegebene Tätigkeiten ohne elektrische Gefährdung, etwa das Bedienen vorgesehener Schalter oder das Auswechseln einer Lampe nach betrieblicher Anweisung.
Wer ist im Betrieb für die elektrische Anlage verantwortlich?
Der Anlagenbetreiber trägt die Gesamtverantwortung für den sicheren Betrieb. Für eine konkrete Arbeit kann ein Anlagenverantwortlicher benannt werden, der den Anlagenzustand beurteilt und die Arbeitsstelle freigibt. Für die eigentliche Durchführung der Arbeit ist der Arbeitsverantwortliche zuständig.
Was bedeutet „unter Leitung und Aufsicht"?
Eine Elektrofachkraft weist die Arbeit an, legt die Schutzmaßnahmen fest, überwacht die Durchführung und muss sich jederzeit von der sicheren Ausführung überzeugen sowie erforderlichenfalls eingreifen können. Sie muss dafür nicht ununterbrochen unmittelbar danebenstehen.
Was sind die fünf Sicherheitsregeln?
Bei Arbeiten im spannungsfreien Zustand gilt diese feste Reihenfolge:
- Freischalten
- Gegen Wiedereinschalten sichern
- Spannungsfreiheit feststellen
- Erden und kurzschließen
- Benachbarte, unter Spannung stehende Teile abdecken oder abschranken
Was ist bei einem Stromunfall zu tun?
Zuerst Eigenschutz beachten, dann den Stromkreis sicher abschalten, den Rettungsdienst alarmieren und Erste Hilfe leisten. Ein Stromdurchgang durch den Körper sollte grundsätzlich ärztlich abgeklärt werden, auch wenn keine sichtbaren Verletzungen vorliegen.
Warum gibt es überhaupt Berufsgenossenschaften?
Die gesetzliche Unfallversicherung soll Arbeitsunfälle, Berufskrankheiten und arbeitsbedingte Gesundheitsgefahren verhindern sowie Verletzte versorgen und wieder eingliedern. Sie geht auf die Sozialgesetzgebung im Deutschen Kaiserreich zurück (Unfallversicherung ab 1884) und ist heute im Sozialgesetzbuch VII geregelt. Berufsgenossenschaften können nach § 15 SGB VII eigene Unfallverhütungsvorschriften erlassen, wie die DGUV Vorschrift 3.
Eine VDE-Norm "empfiehlt" etwas - heißt das, ich kann es auch weglassen?
Nicht ohne Risiko. DIN-VDE-Normen sind rechtlich keine Gesetze, sondern anerkannte Regeln der Technik - deshalb steht oft "wird empfohlen" statt "ist vorgeschrieben". Praktisch bedeutet das: Hält sich ein Betrieb an die anerkannten Regeln der Technik, spricht das im Ernstfall für sorgfältiges Handeln. Weicht er davon ab, kehrt sich die Beweislast tendenziell um - er muss dann erklären können, warum seine Lösung trotzdem mindestens genauso sicher war. Diese Begründung sollte dokumentiert sein, bevor sie gebraucht wird.
Is your situation unique? Then let's clarify your testing obligations directly – structured and without sales pressure.